How to price fire-rated drylining partitions
Last updated 2026-11-05 · 5 min read
To price a fire-rated drylining partition, start from the fire strategy and the specified rating, then price a tested system that meets it exactly. Count the extra board layers and board types, the head and junction details, fire stopping around services, and the time to install and record it. Never price a cheaper build-up that has not been tested.
Fire-rated partitions are where a small pricing shortcut can become a serious problem. The wall has to perform as tested, and the evidence has to show it was built that way. That means the price must include everything the tested system needs, not just the board.
What sets the fire rating you have to meet?
The fire rating comes from the building's fire strategy and the specification, not from the drylining package. Find out for each partition type:
- The fire resistance period required
- Whether the wall must also meet acoustic or height requirements
- Which walls are compartment walls or protect escape routes
- Who is responsible for fire stopping at service penetrations
If the drawings, the schedule and the specification disagree, raise it before you price. Price the assumption you were given and state it in your offer.
Why must you price a tested system?
A fire-rated partition only has its rating when it is built as the system was tested: the same studs, board types, layers, fixings, joints and head details. The manufacturer's published data sets out the build-up.
So price the tested build-up, item by item. If you want to offer an alternative, check that it has its own test evidence, and get it approved by the designer before you rely on it. A cheaper board or wider stud spacing that has not been tested is not the same wall.
What makes a fire-rated wall cost more?
Compared with a standard partition of the same size, look for:
- Extra board layers on one or both faces
- Specialist fire-rated board types
- Closer stud centres or heavier sections where the system needs them
- More screws and specific screw lengths for each layer
- Head details that allow for deflection while keeping the rating
- Junction, corner and abutment details from the system data
- Sealants and fire-rated materials at the perimeter
Each extra layer adds material, screws, labour and jointing. Measure the area once, then build up each layer separately so nothing is missed.
For illustration only: a wall 12 m long and 3 m high is 36 m² of partition. With one layer on each face that is 72 m² of board. If the tested system needs two layers on each face, it is 144 m² of board, twice the boarding and jointing labour, and more screws of a longer length for the outer layers. The partition area has not changed, but the work has doubled.
How do you price fire stopping and penetrations?
Services passing through a fire-rated wall need to be sealed with a tested product for that type of service. Find out early who is doing this work. If it is in your package, count the penetrations by size and type, because each one needs the right product and installation.
If it is not in your package, say so clearly in your offer, and note that your wall's rating depends on it.
How do you allow for inspection and records?
Fire-rated work is often inspected before it is closed up, and the main contractor may want photos and records of each wall. That takes time on site: holding areas open, booking inspections, and recording what was built.
Include this in your price. Ask what records are required at tender stage, so you can price them rather than find out later.
How do you check the price before it goes?
Check that every fire-rated type on the schedule has a matching tested system in your build-up. Compare the rate per m² with your standard partition rate. The difference should be explainable by the extra layers, board types and details. If it is not, something has been left out.
FixMargin is software for UK drylining and interiors subcontractors. A working estimator went from signup to a priced bill of quantities in under 15 minutes, with no help. You can start with a free account, which includes the calculator and one price list: fixmargin.com/signup.
Frequently asked questions
Can I use a cheaper board to win the price?
Only if that build-up has its own test evidence and the designer approves it. Otherwise the wall is not the tested system.
Who is responsible for fire stopping?
It depends on the contract. Ask at tender stage, and state clearly in your offer whether it is included.
Does a fire-rated wall need special head details?
Often yes. Many systems use a deflection head detail to keep the rating where the structure above moves, so check the system data.